Products Introduction

Lift Check Valve

Model

KML110

Caliber

15~800

Pressure

1.6~16.0Mpa

Temperature

-29℃~425℃

Inspection tests

API598

Connection method

Flange

Material

Cast steel, alloy steel, stainless steel 304,316,316L

Applicable medium

Water, steam, thermal oil, oil products, etc.

Product Overview

Lift check valve performance characteristics according to GB12235 standard, valve flap along the center positioning for lifting movement, the liner is made of materials with good performance and small friction coefficient, action, sealing performance is excellent. The products are used in petroleum, chemical, thermal power station and other various working conditions of the pipeline, applicable medium for water, oil, steam and so on. The main role is to prevent the medium backflow, to prevent the pump and its driving motor machine reversal, as well as the discharge of the medium in the container.

Structural Features

Lift check valve can automatically stop the fluid backflow, mainly used to control corrosive or strong corrosive media, the valve body cavity surface covered with optional fluorine plastic, with good corrosion resistance, suitable for different work temperature and fluid pipeline, so as not to pipeline or equipment on the media backflow check valve. Lift check valve can only be installed in the horizontal pipeline.


Lift check valve product structure is reasonable, reliable sealing, excellent performance, beautiful modeling, sealing surface surfacing Co hard alloy, wear-resistant, corrosion-resistant, anti-friction performance, long service life, stem tempering and surface nitriding treatment, good corrosion resistance and anti-friction performance, double sealing, performance is more reliable, more intuitive indication of the lifting position of the valve stem, parts materials, flanges and butt weld dimensions can be reasonably selected according to the actual conditions or user requirements to meet a variety of engineering requirements. The material of parts, flange and butt-welding size can be reasonably selected according to the actual working conditions or user's requirements to meet various engineering needs.


Performance Parameters

Nominal diameter

Main external size and connection size

L

D

D1

D2

b

Z-d

H

15

130

95

65

45

14

4-14

77

20

150

105

75

55

14

4-14

77

25

160

115

85

65

14

4-14

80

32

180

135

100

75

16

4-18

85

40

200

145

110

85

16

4-18

95

50

230

160

125

100

16

4-18

105

65

290

180

145

120

18

4-18

120

80

310

195

160

135

20

8-18

130

100

350

215

180

155

20

8-18

140

125

400

245

210

185

22

8-18

155